MAY-3018 High precision automatic liquid dispensing system
Product introduction:
(Mayzum)MAY-3018High-precision automatic liquid dispensing system, the user receives the device only need to access the raw liquid pipe and water (or other two, a variety of liquids) pipe, set the required ratio of concentration and liquid capacity in the matching system, click the "start ratio" system automatically according to user-set parameters to mix the raw liquid and water, intelligent automatic ratio of liquid supply, without manual intervention.
Scope of application:
Man-machine interface:
Technical parameter:
Concentration ratio range: | 0.0-18.0%(range can be customized, 0-1009% can be customized) |
Concentration measurement accuracy: | 0.1% |
Concentration ratio error: | 0.3% or less |
Matching time: | 5~30 minutes (matching time is related to liquid volume and target concentration) |
Proportioning volume: | ≤1000L/ time (the maximum volume of the ratio is related to the ratio barrel); ≤24T/ day |
Applicable liquid temperature: | 0.0 to 80.0 ℃ |
Concentration measurement frequency: | ≤5 seconds, users can customize |
Power Supply: | AC 220V or AC380V(need to be explained in advance before delivery) |
Control cabinet filling interface: | Mixed liquid import and export: 4 points of external teeth, cutting fluid import and export: 1 inch of external teeth, clean water import and export: 1 inch of external teeth |
Control cabinet size | L550mmXW330mm XH1750mm(can be customized) |
Concentration ratio range: | 0.0-18.0%(range can be customized, 0-1009% can be customized) |
Concentration measurement accuracy: | 0.1% |
Concentration ratio error: | 0.3% or less |
Matching time: | 5~30 minutes (matching time is related to liquid volume and target concentration) |
Proportioning volume: | ≤1000L/ time (the maximum volume of the ratio is related to the ratio barrel); ≤24T/ day |
Applicable liquid temperature: | 0.0 to 80.0 ℃ |
Concentration measurement frequency: | ≤5 seconds, users can customize |
Power Supply: | AC 220V or AC380V(need to be explained in advance before delivery) |
Control cabinet filling interface: | Mixed liquid import and export: 4 points of external teeth, cutting fluid import and export: 1 inch of external teeth, clean water import and export: 1 inch of external teeth |
Control cabinet size | L550mmXW330mm XH1750mm(can be customized) |