Product Introduction:
MAY-3001F intelligent online optical concentration meter is a powerful and practical online concentration measurement system. The standard display controller is equipped
with MAYZUM-V6.3 concentration data processing system, which has probe state self-diagnosis function, self-modeling, measurement and titration curve correction, linear
error correction, RI calibration, custom multi-point temperature compensation value, Self-cleaning control, upper and lower limit setting and acousto-optic alarm and other functions,
adapt to a variety of complex working conditions, according to the user's field conditions flexible setting, higher accuracy, good repeatability, more reliable data.
Scope of application:
Widely used in ammonia, cutting fluid, juice, beer, urea, NMP, DMAC, DMF, hydrogen
Sodium oxide, cleaning agent, ethylene glycol, food and beverage, collagen, acetic acid emulsion, coffee...... Etc.
Technical parameters:
Product model | MAY-3001F-70 | MAY-3001F-HT(High temperature resistant model) |
Measuring items | Refractive index (nD), Brix(temperature compensation in accordance with sucrose), concentration (Conc), temperature (C) | |
Sugar degree range | 0.0 to 70% | 0.0 to 90% |
Refractive index range | 1.3330 ~ 1.4655 | 1.3330 ~ 1.5177 |
Resolution | 0.01%, refractive index 0.00002, temperature 0.1 ° C | |
Measurement accuracy | ±0.1%, refractive index 0.0001, temperature 0.5℃ | |
Temperature compensation | Automatic temperature compensation | |
Liquid contact material | SS316L+ sapphire (optional: PTFE, Hastelloy, titanium, tantalum) | |
Process temperature range | 0 ~ 70 ℃ | - 10 ~ 100 ℃ |
Installation connection method | 1.5 "Fast card | 2 "Fast card |
Input power | Standard: 24VDC; Optional: 100-240VAC/50-60 Hz | |
Signal Output | □4-20mA, □RS485/232 digital quantity, port switching quantity (abnormal alarm, upper and lower limit 2 output) | |
Protection level | Liquid contact section IP67 | |
Pressure tolerance range | 1MPa | |
Explosion-proof rating | Ex d IICT4 Gb |
Product model | MAY-3001F-70 | MAY-3001F-HT(High temperature resistant model) |
Measuring items | Refractive index (nD), Brix(temperature compensation in accordance with sucrose), concentration (Conc), temperature (C) | |
Sugar degree range | 0.0 to 70% | 0.0 to 90% |
Refractive index range | 1.3330 ~ 1.4655 | 1.3330 ~ 1.5177 |
Resolution | 0.01%, refractive index 0.00002, temperature 0.1 ° C | |
Measurement accuracy | ±0.1%, refractive index 0.0001, temperature 0.5℃ | |
Temperature compensation | Automatic temperature compensation | |
Liquid contact material | SS316L+ sapphire (optional: PTFE, Hastelloy, titanium, tantalum) | |
Process temperature range | 0 ~ 70 ℃ | - 10 ~ 100 ℃ |
Installation connection method | 1.5 "Fast card | 2 "Fast card |
Input power | Standard: 24VDC; Optional: 100-240VAC/50-60 Hz | |
Signal Output | □4-20mA, □RS485/232 digital quantity, port switching quantity (abnormal alarm, upper and lower limit 2 output) | |
Protection level | Liquid contact section IP67 | |
Pressure tolerance range | 1MPa | |
Explosion-proof rating | Ex d IICT4 Gb |