Model: MAY-300BH/MAY-600BH
Working principle: According to GB/T21862, GB/T15223, GB/T6750, ASTMD1475, ISO2811-2, ISO1675, DIN53217-3...... Such as the national standard, the use of Archimedes impregnated Gamma ball volume replacement method, with special microcomputer software special design, accurate reading of the measured value.
Suitable for: dispersion paint, ceramic paste, ink, liquid resin, grinding liquid, asphalt, chocolate liquid, emulsion, liquid adhesive, medium and high viscosity liquid......
Brief introduction of functions:
1, one key to read the density/concentration value of the solution, the operation is simple and clear, simple training can be operated by itself.
2, automatic calibration of Gamma ball volume value, weight and volume is not limited.
3, improve the use of Gay Rusack and Hubbard specific weight bottle mouth sticking problem, improve the use of solvent to wipe Q88 cup overflow
Export spill paint trouble, using 304 stainless steel precision machining, smooth surface easy to clean, just simply rinse or wipe with paper towels.
4, only about 40ml of sample, one-key direct reading density and concentration value,
5, can use disposable degradable environmental protection paper cup to load samples, environmental protection, safe, easy to clean. Hygienic design,
The sample test is pollution-free and can be recycled twice to reduce the loss of valuable solution.
6, automatic temperature compensation, one key compensation air buoyancy and temperature drift caused by the error, improve the accuracy of the test.
7, built-in printer, after the measurement is completed, one-click print data report
(The report includes: company name, sample name, tester, test time, test results; As shown below).
Technical parameter:
brand | Mayzun(seconds accurate) | ||
Model number | MAY-300BH | MAY-600BH | MAY-120BH |
Weighing range: | 0.01-300g | 0.01 g ~ 600g | 0.001 g - 150 g |
Density accuracy | 0.001 g/cm3 | 0.0001g/cm 3 | |
Density repeatability accuracy | + / - 0.001 g/cm3 | ±0.0001g/cm3 | |
Concentration repeatability accuracy | Plus or minus 0.1% | Plus or minus 0.03% | |
Density, concentration range | 0.001~99.999g/cm³, 0.1%~100% | ||
Type of measurement | Any liquid can be measured | ||
Measurement Principle | Principle of Archimedes displacement method, the test time is about 5 seconds | ||
Liquid pattern measurement steps | Take about 25~50ml of the sample, put the standard block in the sample, and read the density (specific gravity) and concentration % with one key | ||
The results show | Liquid density, specific gravity, concentration % | ||
Parameter setting | Standard block density, concentration linear parameters, upper and lower limits of specific gravity can be set | ||
Correction mode | One click automatic correction | ||
Print Specifications | 58mm, thermal print | ||
Output mode | RS-232C standard communication interface, convenient test data output and printing | ||
Power Supply | AC100V-240V ,50HZ/60HZ (Default European standard plug, export power supply needs to be customized, please note before ordering) | ||
Temperature and humidity range | Allowable ambient temperature: 0~45℃; Allowable relative humidity: less than 80% | ||
Power Supply | AC~220V /50FHZ(Export power supply needs to be customized, it can be noted before ordering) | ||
Other parameters: | Outer packing size: 395*195*330mm; Body size: 310*295*285mm Net weight: 7.5kg; Gross weight: 9.5kg(Export customs code HS:90160090) |
brand | Mayzun(seconds accurate) | ||
Model number | MAY-300BH | MAY-600BH | MAY-120BH |
Weighing range: | 0.01-300 - g | 0.01 g ~ 600 g | 0.001 g - 150 - g |
Density accuracy | 3 0.001 g/cm | 0.0001g/cm 3 | |
Density repeatability accuracy | 3 + / - 0.001 g/cm | 3 ±0.0001g/cm | |
Concentration repeatability accuracy | Plus or minus 0.1% | Plus or minus 0.03% | |
Density, concentration range | 0.001~99.999g/cm³, 0.1%~100% | ||
Type of measurement | Any liquid can be measured | ||
Measurement Principle | Principle of Archimedes displacement method, the test time is about 5 seconds | ||
Liquid pattern measurement steps | Take about 25~50ml of the sample, put the standard block in the sample, and read the density (specific gravity) and concentration % with one key | ||
The results show | Liquid density, specific gravity, concentration % | ||
Parameter setting | Standard block density, concentration linear parameters, upper and lower limits of specific gravity can be set | ||
Correction mode | One click automatic correction | ||
Print Specifications | 58mm, thermal print | ||
Output mode | RS-232C standard communication interface, convenient test data output and printing | ||
Power Supply | AC100V-240V ,50HZ/60HZ (Default European standard plug, export power supply needs to be customized, please note before ordering) | ||
Temperature and humidity range | Allowable ambient temperature: 0~45℃; Allowable relative humidity: less than 80% | ||
Power Supply | AC~220V /50FHZ(Export power supply needs to be customized, it can be noted before ordering) | ||
Other parameters: | Outer packing size: 395*195*330mm; Body size: 310*295*285mm Net weight: 7.5kg; Gross weight: 9.5kg(Export customs code HS:90160090) |